Dacor CM24P-1 Anleitung zur Fehlerbehebung

Stöbern Sie online oder laden Sie Anleitung zur Fehlerbehebung nach Kaffeemacher Dacor CM24P-1 herunter. Dacor CM24P-1 Troubleshooting guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Quick Reference Guide

Technical Diagnostic Quick Reference Guide Technical Assistance Line 800-353-2267

Seite 2 - Dacor Contact Information:

Dacor Discovery Oven Diagnostic Mode: Models: EO, PO, MOV, MOH, SINGLES AND DOUBLES, 27” A

Seite 3

Error Code: Description of Failure: Page: Error Code: Description of Failure: Page:U20 OVER TEMP (UPPER/SINGLE) Cook temp over 610F for 2 min 9-34 U43

Seite 4 - (bottom of page)

RequirementPress each number key. The number will be displayed on the control display.Press the BAKE key. Verify bake element is on, measure amperage

Seite 5

Displayed Error CodeError Condition Software Logic Description C01 Shorted Key Failure Release of Key not seen in 2 mionutes. Membrane Shorted Key Fai

Seite 6

Dacor: ER Range Quick Set Guide Control Panel Position: The Control panel can be swiveled to a 50° angle for easier view

Seite 7

111 Error Code: Dacor: ER Range Fault Code Troubleshooting Guide Description: Potential Cause: How to Diagnose / Repai

Seite 8

Dacor ER Duel Fuel Range ERC Diagnostic Test Models: ER30D, ER36D, ER48D and ER60D To access the ERC Diagnostic Test: Turn circuit breaker off or d

Seite 9

Test 16: Convection Fan right/large oven side Press the right/large oven side PURE CONV. Key and verify that the CONV. And ON icons are lit. Verify t

Seite 10 - Dacor Tec-Line: 800-353-2267

Dishwasher Factory Test Mode 24” Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24 (all colors), MDV24S & MDH24S 30” Models: ID30, ED30S

Seite 11

Dishwasher Fault Codes: 24” Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24 (all colors), MDV24S & MDH24S Fault Cause Effect Sol

Seite 12 - Lower Oven Test

Dacor Contact Information: Dacor Customer Service: 800-793-0093 X 2813 [email protected] Dacor Distinctive Service: 800-793-

Seite 13

Dishwasher Diagnostic Quick Reference Sheet. S1 L1 L2 L3 L4 L5 L6

Seite 14 - Dacor: ER Ran

Dishwasher Control Programming and Fault Code Reference Sheet Control Programming DDWF24S When the power is switched on for the first time after rep

Seite 15

Programming Mode: Note: The Programming Code is located on the Serial Plate. 1. Press and Hold the “Door Alarm” Keypad. 2. Press and hold the

Seite 16 - Tec-Line: 800-353-2267

Service Test 121 – Open Damper Test Press the Refrigerator Up Keypad and Down Keypad to toggle Damper (OP) open and (CL) Closed. Note: If Damper is op

Seite 17

Programming Mode: NOTE: The Program Code is located on the Serial Plate after the word Code. 1. Press and hold the WATER Keypad. 2. Press and h

Seite 18

Service Test - 151 Fresh Food Door State • Will show state of Fresh Food Door. OP (open) CL (closed). NOTE: By pushing either fresh food door switches

Seite 19 - Dishwasher Fault Codes:

Service Test Mode There are several test modes available through the diagnostic system. Use of these test modes can greatly decrease the

Seite 20

Thermistor Tests: This test will give a “GO – NO GO” test of all thermistors. Pressing the Power Interrupt Button will report the condition of the

Seite 21 - Fault Codes:

Service Test 17 – Compressor Minimum Speed The compressor should have been off for at least five minutes prior to this test. If the off time is no

Seite 22

Service Test 28 – Actuator Switch This test displays the current state of the dispenser actuator (paddle switch) as read by the Main Control board

Seite 23

Technical Diagnostic Quick Reference Index Dacor Contact information - Page: 2 Index - Page: 3 & 4 Serial Number Format – Page: 5 Oven Tempera

Seite 24 - Model: EF36IWFSS

Diagnostic Test Mode There are several test modes available through the diagnostic system. Use of these test modes can greatly decrease

Seite 25

Service Diagnostic Mode Chart Water Filter Input (WFI) Test To confirm that the water valves are being monitored by the WFI control, follow the pr

Seite 26 - Service Test Mode

Accessing the Main Programming Menu: Remove the drip tray. Unlock the front panel door. When the door is open, the buttons on the front of th

Seite 27

Turning Pre-brew On and Off: 1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Pre-brew” appears on the display

Seite 28

Technical Diagnostic Quick Reference Index Continued… ER-Range Quick ERC Test – Page: 16 & 17 Range Models: ER30D, ER30DSR, ER36D, ER48D Classic

Seite 29 - FoodSaver™ TEST MODE

Dacor Serial Number Format: **Prior to the 38th week of 2002 the serial number format was: FC2371234 In 2002 Dacor changed the serial number format sl

Seite 30

Dacor Technical Assistance: 800-353-2267 Oven Temperature Calibration Instructions: Classic Wall Oven & Range Temperature Calibration Proc

Seite 31

Dacor Technical Assistance: 800-353-2267 Oven Temperature Calibration Instructions Continued: ER-Dual Fuel Range Temperature Calibration Procedur

Seite 32

There are two ways to access the program. Option 1: Turn circuit breaker off or disconnect power to unit, count to five and then turn power b

Seite 33

-F0- Shorted Or Jammed Input Device This failure will appear if a shorted or jammed input device is defective. Possible causes include shorted

Kommentare zu diesen Handbüchern

Keine Kommentare