PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
3.1
30 Inch and 36 Inch Wide,
Millennia
®
Electric Cooktops
PRODUCT DIMENSIONS - ETT365-2 AND METB365-1
(ETT365-2 SHOWN)
36 1/4" *
(921 mm)
34 3/8"
(873 mm)
19 3/8"
(495 mm)
21 1/4" *
(540 mm)
4" (102 mm)
Chassis height
30 1/4" *
(768 mm)
28 3/8"
(721 mm)
19 3/8"
(495 mm)
21 1/4" *
(540 mm)
4" (102 mm)
Chassis height
PRODUCT DIMENSIONS - ETT304-1 AND MET304
(ETT304-1 SHOWN)
ETT304-1, ETT365-2, MET304 and METB365-1
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
Document # PG03-001 Revised 05/06/10 Page 1/3
NOTES:
The cooktop is supplied with a flexible, 48 inch long 1.
power conduit consisting of two (2) insulated hot lead
conductors (L1 and L2) and one (1) insulated ground
conductor. There is no neutral connection. All leads are
copper. The conduit is connected to the right corner of
the cooktop. Do not connect the ground wire to neutral.
Tested in accordance with the latest edition of ANSI 2.
Z21.1 and U.L. 858 Standard for household cooking
appliances.
These cooktops are not approved for recessed 3.
installation.
Model No. Electrical Circuit Required
Total Connected
Load*
Minimum Supply Wire Size
Line and Ground Connections
ETT304-1 240 Vac, 60 Hz, 40 Amps. 6.9 kW (29 Amps.)
No. 8 AWG
ETT365-2 240 Vac, 60 Hz, 40 Amps. 9.1 kW (38 Amps.)
MET304 240 Vac, 60 Hz, 40 Amps. 6.9 kW (29 Amps.)
METB365-1 240 Vac, 60 Hz, 50 Amps.* 9.6 kW (40 Amps.)
* For reference only, See the product data label on bottom of unit for exact specifications.
ELECTRICAL SUPPLY REQUIREMENTS
WARNING
Observe all governing codes and ordinances during planning •
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the •
accompanying installation instructions.
* For units with stainless steel trim, other units may be up to 1/8" less.
Seitenansicht 0
1 2 3

Inhaltsverzeichnis

Seite 1

PLANNINGGUIDEwww.Dacor.com Phone: (800) 793-0093 Specications subject to change without notice.Install all appliances according to accompanying

Seite 2 - Electric Cooktops

PLANNINGGUIDEwww.Dacor.com Phone: (800) 793-0093 Specications subject to change without notice.Install all appliances according to accompanying

Seite 3

PLANNINGGUIDEwww.Dacor.com Phone: (800) 793-0093 Specications subject to change without notice.Install all appliances according to accompanying

Kommentare zu diesen Handbüchern

Keine Kommentare