Electrical Installation
1. Run the wiring used to supply power from the installed
downdraft vent or hood to the blower parallel to the
duct work.
2. Make sure that power to the downdraft vent or hood is
disconnected or turned off at the circuit breaker or fuse
box.
3. With the UL certified strain relief attached to the end
of the wiring/conduit, feed the wires into the electrical
access hole on the under side of the blower and attach
it.
4. From inside the blower assembly, strip the three wires.
5. Connect the black (L1) wire to the L2 blower power ter-
minal (see Figure 10). Tighten the terminal screw firmly
into place. IMPORTANT: The L2 (hot) terminal on the
blower has the BLUE wire from the blower wiring har-
ness connected to it.
6. Connect the white (neutral) wire to the N2 blower
power terminal (see Figure 10). Tighten the terminal
screw firmly into place. IMPORTANT: The neutral (N2)
terminal on the blower has the BLACK wire from the
blower wiring harness connected to it.
7. Connect the green (GND) wire to the GND blower
power terminal (see Figure 10). Tighten the terminal
screw firmly into place.
8. Check the wires from the blower wiring harness to
make sure that they are firmly attached to the terminal
according to Figure 10. Reconnect any wires that are
loose. Make sure all terminal screws are tight.
9. Replace the blower’s top cover and screws. Seal the
edges of the cover and screw heads if the unit will be
exposed to the weather.
10. Secure the other end of the wiring/conduit to the hood
or downdraft vent and connect the wires according to
the hood or downdraft vent installation instructions.
Verifying Proper Operation
WARNING
Read the downdraft vent or hood use and care manual
completely before operation.
Test the blower operation according to the Verify Proper
Operation section of the hood or downdraft vent installa-
tion instructions.
If the blower does not work after having been properly
installed, contact Dacor Distinctive Service at (800) 793-
0093 ex. 2822. Do not attempt to repair the unit yourself.
Dacor is not responsible for the costs required to correct
problems caused by a faulty installation.
Roof
Blower
Cutout
Wiring/conduit
connected to blower
Figure 9:
Wiring/Conduit Connection
L2 N2 GND
Not
used
Wires
from hood/
downdraft
vent
To blower
wiring harness
Black
Black
Blue
White
Green
Green
Figure 10: Wiring Diagram