Programming Mode: Note: The Programming Code is located on the Serial Plate.
1. Press and Hold the “Door Alarm” Keypad.
2. Press and hold the Freezer Temperature Down Keypad.
3. Release the “Door Alarm” Keypad and wait 3 seconds.
4. The Control will display “PE” to indicate the Programming Mode.
5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more.
6. The Control will display the current Program Code. This code should be validated with the Program Code printed on
the Serial Plate. If the Program Code is correct, the Program Mode can be exited by closing the Refrigerator Door(s).
7. Press the Refrigerator Temperature Up or Down Keypad to change the digit value with each press.
8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad to select the next digit.
9. Once the desired Program Code is entered, press and hold the Freezer Temperature Down key until the Program
Code begins flashing indicating it has been saved.
Note: If you attempt to enter an invalid Program Code the control will not save the new code, but will beep (the unit
will not run with a Program Code of 0000). Once the Program Code has been saved the Programming Mode is exited
by closing the Refrigerator Door(s). If the new code is not correct this process should be repeated after closing the
Refrigerator Door(s).
Forced Defrost Mode:
The forced defrost function is performed using the refrigerator display and keypad. Enter the Forced Defrost Mode by
the following:
1. Press and Hold the “Door Alarm” Key.
2. Press and Hold the Refrigerator Temperature Down Keypad.
3. Release the “Door Alarm” Keypad and wait 3 seconds. Fd appears in left display.
4. Press the Refrigerator Down Keypad again. Sh appears in the right display.
5. Press again to force defrost, Fd and Sh will flash in Display indicating unit is in defrost.
Service Test Mode:
To enter the Service Test Mode follow these directions.
1. Open the Fresh Food Door and press and hold the “Door Alarm” Keypad.
2. Press and Hold Refrigerator Temperature Up Keypad.
3. Release the “Door Alarm” Keypad and wait 3 seconds. SE appears in the left display.
4. Press the Refrigerator Up Keypad again.
5. Display will show 001 in the left display and numeric or dashes in right display. Test # 001 is for Factory Use Only.
6. Press Freezer Up Keypad and Freezer Down Keypad to toggle through Service Test Number.
Service Test 001 – Factory Use Only
Service Test 101 – Defrost Heater & Defrost Circuit Test
Press the Refrigerator Up Keypad and Refrigerator Down Keypad to energize or de-energize the Defrost Circuit. The
display will read OFF when de-energized, OP when energized with an open defrost thermostat and CL when energized
with a closed defrost thermostat.
Service Test 102 – Compressor/Condenser Fan Test
Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Compressor/Condenser Fan On and Off.
Service Test 111 – Fresh Food Fan Test (if equipped)
Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle the Fresh Food Fan On and Off. Note:
Display will show state OFF or DC Voltage
Service Test 112 – Evaporator/Freezer Fan Test
Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle the Fresh Food Fan On and Off. Note:
Display will show DC Voltage.
Dacor 36” Freestanding Refrigerator Programming and Diagnostics:
Models: EF36BNDFSS, IF36BNDFSF, EF36LNDFSF, EF36RNDFSS, IF36INDFSF, EF36BNFSS, EF36LNFSS,
EF36RNFSS, & EF36BNNFSS and PF36BNDF (all colors: AG, BK, BU, GN, SG and TS).
PG: 22
Seitenansicht 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 32 33

Kommentare zu diesen Handbüchern

Keine Kommentare